Checking internal components
When checking the internal components the
PRISMAsync has to be opened. See
Access internal
components
on page 67.
NOTE
Please follow standard Electro Static Discharge (ESD) precautions when handling electronic
components.
Check the following:
Procedure
1.
No strange objects are inside the
PRISMAsync.
2.
Look for obvious loose boards. Reseat each board including DDR3 modules.
3.
Look for obvious loose connectors. Reseat each connector firmly.
4.
Be sure that HDDs are connected to the right SATA port. See
Replace the Hard Disk Drives
on
page 74
Checking internal components