EasyManuals Logo

Canon PRISMAsync v3.2 User Manual

Canon PRISMAsync v3.2
164 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #112 background imageLoading...
Page #112 background image
Checking internal components
When checking the internal components the
PRISMAsync has to be opened. See
Access internal
components
on page 67.
NOTE
Please follow standard Electro Static Discharge (ESD) precautions when handling electronic
components.
Check the following:
Procedure
1.
No strange objects are inside the
PRISMAsync.
2.
Look for obvious loose boards. Reseat each board including DDR3 modules.
3.
Look for obvious loose connectors. Reseat each connector firmly.
4.
Be sure that HDDs are connected to the right SATA port. See
Replace the Hard Disk Drives
on
page 74
Checking internal components
112 Chapter 10 - Troubleshooting
PRISMAsync V3.2

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Canon PRISMAsync v3.2 and is the answer not in the manual?

Canon PRISMAsync v3.2 Specifications

General IconGeneral
BrandCanon
ModelPRISMAsync v3.2
CategoryController
LanguageEnglish

Related product manuals