62-11785 5–22
SETPOINT(S) & RANGE LOCK
DECIMAL DISPLAYED DISPLAYED = setpoint will be shown with a
decimal and temperatures may be selected to a
tenth of a degree.
NOT DISPLAYED NOT DISPLAYED = setpoint will not be shown with
a decimal. All other temperatures will still be
displayed with a decimal.
MIN SETPOINT -22°F TO 90°F
(-30°C to 32°C)
in 0.1°F or °C increments
Indicates to the main microprocessor the desired
minimum allowable set point.
MAX SETPOINT -22°F TO 90°F
(-30°C to 32°C)
in 0.1°F or °C increments
Indicates to the main microprocessor the desired
maximum allowable setpoint.
RANGE 1 LOCK
OR
RANGE 2 LOCK
OFF
START-STOP
CONTINUOUS
OFF = If both Range Locks are OFF, the unit will
operate normally.
If either Range 1 or Range 2 is not OFF, the unit will
operate as selected whenever the setpoint is within
that range.
START-STOP = The unit will always operate in
Start-Stop whenever the setpoint is between the
minimum & maximum temperatures for that range
(refer to the following sub-configurations).
CONTINUOUS = The unit will always operate in
Continuous Run whenever the setpoint is between
the minimum & maximum temperatures for that
range (refer to the following sub-configurations).
RANGE 1 (or 2) MINIMUM
TEMPERATURE
-22°F TO 90°F
(-30°C to 32°C)
in 0.1°F or °C increments
Select the lowest temperature desired for this
Range.
RANGE 1 (or 2) MAXIMUM
TEMPERATURE
-22°F TO 90°F
(-30°C to 32°C)
in 0.1°F or °C increments
Select the highest temperature desired for this
range.
START-STOP SETTINGS
CURRENT FOR S/S SHUTOFF 7.0A
1A TO 10A (in 0.5A
increments)
In Start-Stop Operation the charging current must
drop below this value before the unit is allowed to
shut down.
Table 5–1 Configuration Settings
(Refer to Section 5.2.3 for instructions on entering Configuration settings)
Configuration Selections Description

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Carrier TRANSICOLD VECTOR 8100 and is the answer not in the manual?

Carrier TRANSICOLD VECTOR 8100 Specifications

General IconGeneral
BrandCarrier TRANSICOLD
ModelVECTOR 8100
CategoryRefrigerator
LanguageEnglish

Related product manuals