62-11785 5–22
SETPOINT(S) & RANGE LOCK
DECIMAL DISPLAYED DISPLAYED = setpoint will be shown with a
decimal and temperatures may be selected to a
tenth of a degree.
NOT DISPLAYED NOT DISPLAYED = setpoint will not be shown with
a decimal. All other temperatures will still be
displayed with a decimal.
MIN SETPOINT -22°F TO 90°F
(-30°C to 32°C)
in 0.1°F or °C increments
Indicates to the main microprocessor the desired
minimum allowable set point.
MAX SETPOINT -22°F TO 90°F
(-30°C to 32°C)
in 0.1°F or °C increments
Indicates to the main microprocessor the desired
maximum allowable setpoint.
RANGE 1 LOCK
OR
RANGE 2 LOCK
OFF
START-STOP
CONTINUOUS
OFF = If both Range Locks are OFF, the unit will
operate normally.
If either Range 1 or Range 2 is not OFF, the unit will
operate as selected whenever the setpoint is within
that range.
START-STOP = The unit will always operate in
Start-Stop whenever the setpoint is between the
minimum & maximum temperatures for that range
(refer to the following sub-configurations).
CONTINUOUS = The unit will always operate in
Continuous Run whenever the setpoint is between
the minimum & maximum temperatures for that
range (refer to the following sub-configurations).
RANGE 1 (or 2) MINIMUM
TEMPERATURE
-22°F TO 90°F
(-30°C to 32°C)
in 0.1°F or °C increments
Select the lowest temperature desired for this
Range.
RANGE 1 (or 2) MAXIMUM
TEMPERATURE
-22°F TO 90°F
(-30°C to 32°C)
in 0.1°F or °C increments
Select the highest temperature desired for this
range.
START-STOP SETTINGS
CURRENT FOR S/S SHUTOFF 7.0A
1A TO 10A (in 0.5A
increments)
In Start-Stop Operation the charging current must
drop below this value before the unit is allowed to
shut down.
Table 5–1 Configuration Settings