6–1 62-11785
SECTION 6
MESSAGECENTER MESSAGES
6.1 MESSAGECENTER MESSAGES
The following table lists common messages which do not appear in other lists in this manual and a description of
their meaning. Refer to Section 7 for a list of Alarm messages. Refer to Section 3.14 for a list of Unit Data mes-
sages. Refer to Section 3.17 for a list of Functional Parameter messages. Refer to Section Section 5.2.3 for a list
of Configuration messages.
Table 6–1 MessageCenter MESSAGES
Message Description
ACTIVE
This message will appear in the MessageCenter along with the cur-
rent IntelliSet indicating that the IntelliSet is active and none of its
settings have been modified.
ACTIVE ALARM LIST CLEARED
The list of active alarms in the microprocessor has been erased.
(This does not remove alarms from the DataLink data recorder.)
ALL ALARMS CLEARED
The list of active and inactive alarms in the microprocessor alarm
lists have been erased. (This does not remove alarms from the Da-
taLink data recorder.)
BUZZER OFF IN X MINS
The Buzzer circuit has been energized in Component Test Mode.
The Buzzer circuit will continue to be energized for the number of
minutes shown.
CANNOT ENTER TRIP START
Cannot enter Trip Start. A problem has been detected within the Da-
taLink data recorder.
CANNOT START DEFROST CYCLE
Due to current unit conditions, the defrost cycle cannot be started.
Refer to Defrost Section 3.11 and Section 8.7.12.
CANNOT START PRETRIP
Due to current unit conditions a Pretrip test cannot be started. Refer
to Pretrip Section 3.6.
CHANGE INTELLISET TO EXIT
The IntelliSleep IntelliSet is active. Alternates with “INTELLI- SLEEP
MODE” at 5 second interval whether unit is running or not.
CHARGE MODE-HOLD = TO EXIT
Service Mode has the refrigeration system set so that it can be
charged with refrigerant through the liquid line service valve. Press
the = key to manually exit, or wait until the charging is complete.
CHECK AT NEXT SERVICE INTERVAL
The unit needs to be checked at next service interval.
There is currently an active non-shutdown alarm in the alarm list.
CHECK DOOR
The door switch indicates that a refrigerated compartment door is
not closed.
COMPONENT TEST MODE
Pressing the = key while this message is highlighted will allow user
access to Component Test Mode.
CONTINUOUS LOCKED
The current setpoint is within a range that has been locked into the
Continuous Run Mode. Start-Stop can not be selected.
CONTINUOUS RUN MODE SELECTED
The unit operating mode has been changed from Start-Stop to Con-
tinuous Run.
DATA RECORDER FAILURE The microprocessor has stopped recording Unit Data.
DEFROST CYCLE STARTED The unit has gone into defrost.
DEFROST The unit is in the defrost cycle.
DOOR OPEN A refrigerated compartment door is open.
ENTERING SERVICE MODE The initial message for Service Mode.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Carrier TRANSICOLD VECTOR 8100 and is the answer not in the manual?

Carrier TRANSICOLD VECTOR 8100 Specifications

General IconGeneral
BrandCarrier TRANSICOLD
ModelVECTOR 8100
CategoryRefrigerator
LanguageEnglish

Related product manuals