7-MAINTENANCE
Hydraulicsystembreather-Clean
1.FollowMachinesafetyposition.(ReferEngine-Safety
rules).
2.Cleantheareaaroundthecap.
3.Removethecap(1)usingthewrench(2)suppliedwith
themachine.
4.Makesurethatnodirtenterthehydraulicoiltank.
5.Useasuitablegreasesolventtowashthecap(1).
6.Air-drythecap.
7.Retightentheplug.
CAUTION
Flyingdebris!
Compressedaircanpropeldirt,rust,etc.into
theair.Weareyeandfaceprotectionwhenus-
ingcompressedair.
Failuretocomplycouldresultinminorormod-
erateinjury.
C0049A
PTIL12TLB0512AB1
7-30