8-TROUBLESHOOTING
Hydraulicsystems-Troubleshooting
Problem
PossibleCauseCorrection
Allcircuitsfailtooperate
Pumpdriveinoperative
Checkandrepairasnecessary
Lowoillevel
Checkthelevelandtopup
RestrictedpumpsuctionlineInspectthesuctionlineandthetankand
repairasnecessary
Slowoperationorlossof
powerinallcircuits
Wornpump
Makeapumpperformancetest,replace
andresealasnecessary
RestrictedpumpsuctionlineInspectthesuctionlineandthetankand
repairasnecessary
Loadsensingpressurereliefvalveincor-
rectlyadjusted
Makeasystempressuretest
HydraulicspeedsolenoidvalveinoperativeMakeasystempressuretest