Large X emb adjust it allows to align the zero of the embossing fields
with the left edge of the Medical Red Alert Tag
plate.
Each unit corresponds to 0.18 mm
Y emboss adjustment it allows to align the zero of the embossing fields
with the bottom edge of the tag.
Each unit corresponds to 0.125 mm
X load adustment it allows to adjust the tag picking position
along the X axis.
Each unit corresponds to 0.18 mm
Y load adustment it allows to adjust the tag picking position
along the Y axis.
Each unit corresponds to 0.125 mm
Small tag norm punch it allows to adjust the pressure that the hammer
must exert on standard characters during the
embossing of Dog Tag plates.
With this function the relief of the embossed
character or the depth of the engraved character
can be adjusted.
Small tag OCR punch it allows to adjust the pressure that the hammer
must exert on characters block during the
embossing of the Dog Tag plates.
With this function the relief of the embossed
character or the depth of the engraved character
can be adjusted.
Large tag norm punch it allows to adjust the pressure that the hammer
must exert on standard characters during the
embossing of Medical Red Alert Tag plates.
With this function the relief of the embossed
character or the depth of the engraved character
can be adjusted.
Large tag OCR punch it allows to adjust the pressure that the hammer
must exert on characters block during the
embossing of Medical Red Alert Tag plates.
With this function the relief of the embossed
character or the depth of the engraved character
can be adjusted.
Reversed holes It indicates if the types of punches present on the
machine are reversed so that the relief is
downwards. This function is adopted if you need to
write very close to the bottom edge of the tag.
Punches are OPTIONAL