3-7
OPERATOR’S MANUAL PRO SERIES
3 INSTALLATION
3.6 CHOOSING THE WORKING PLACE
Install the machine at least 0,6 m of height. Take care
that the place where you install the machine is conform
to the environmental requirements at par.1.15. Leave at
least 0,3 m of distance from each side of the machine
and the closer walls or barriers in order to permits the
better access to connectors and the proper air
conditioning. The opening of the covers require 0,4 m
free space also above the cover. Take care that the
support where you put the machine does not amplify the
noise level over the allow level (see par. 1.15) and that
the work station's strength is suitable to support the
machine. Do not install the machine on unstable
surfaces.
3.7 START UP
Once installed the machine can be switched on with
main switch, on the one display will appear the
message:
E-00 POWER ON STANDBY STATUS - PRESS
START
Press the START key on right side of the front panel
beside the display. This activates a general reset which,
when completed, will leave another message on the
display to indicate the Ready Mode of the machine.
MODEL C1000 PRO SERIES V.Y.YY READY
If the machine does not start control that the power
supply is correctly set and that the main fuse has not
been burnt.
For other breakdowns please refer to the Chapter “Error
Messages and Problem Solving.
ATTENTION! IF THE DISPLAY IS TURNED ON BUT
NOTHING APPEARS ON THE SCREEN SWITCH THE
MACHINE OFF AND CALL THE TECHNICAL
ASSISTANCE.
The machine is now ready to run. If the Software
included is to be used for the production of plastic cards
the machine can start the production immediately. If
however another Software is used it is necessary to
control the relative parameters for the communications
protocol. To do this one enables the Machine Setup
from the console (Annex A).