6 TROUBLESHOOTING
6 - 8
OPERATOR’SMANUAL PRO SERIES
CODE MSG POSSIBILE INTERVENTO
E-72 FEEDER MOTOR
ERROR - PRESS
START
The bridge motor is not running properly.
Check clamping of pulleys and tightening of screws;
check card handling and ensure that there is nothing mechanical
obstructing movement. Check photocell. Reset the machine before
resuming operation.
E-73 PWR-ON
STAND-BY
STATUS-PRESS
START
The unit has been turned ON.
Start Host computer to proceed with job operation.
E-74 THERMOERROR /
CHECK PRINTER
Thermographic error.
This error is managed by Host during operation through Parallel Port.
Press start to proceed operation.
E-75 CHIP ERROR - PRESS
START
Chip programming error.This error is managed by Host when a chip
programming error has occurred. Press START to proceed operation.
E-80 BCC ERROR - PRESS
START OR FEED
Error calculating the BCC of the serial message. Control the setup
configuration of the machine or Host message strings.
E-81 PARITY ERROR -
PRESS START OR
FEED
Host communication error. Control the setup configuration of the
machine or Host message strings.
E-82 NO FIELD IN MASK -
PRESS START OR
FEED
The punching mask data transmitted is incorrect. Check the data
transmitted.
E-83 CODE ERROR - PRESS
START OR FEED
A data error has been detected on the string transmitted by the PC in
CIM protocol.
Check the data transmitted.
E-84 FIELDS OVERFLOW The string transmitted by the PC shows more punching lines than those
foreseen by the mask data. Check the data transmitted.
E-85 BAD FORMAT - PRESS
START OR FEED
The text or format messages sent by the computer contain incorrect
characters. Control the text and setup of the protocol parameters.
E-86 ENCODER ERROR Wrong or invalid encoding data.
Check JOB and data files again.
E-87 LONG FIELD - PRESS
START OR FEED
The string transmitted by the PC shows a number of characters
exceeding the accepted number, on one or more punching lines. Check
the data transmitted again.
E-88 HEADER FORMAT
ERROR - PRESS
START
There is an error on the string transmitted by the PC (in
MULTIEMBOSSER protocol).
Check the data transmitted again.
E-89 MODE CHECK ERROR
- PRESS START
Check the protocol data.
E-90 THERMO BAD FORMAT
- PRESS START OR
FEED
Protocol error. The command has an invalid thermo format.
Verify the thermographic field string sent to the machine.
E-92 CHIP CODE ERROR -
PRESS START OR
FEED
Protocol error. The command has an invalid chip format.