EasyManua.ls Logo

Circontrol Post eVolve Smart Series - Page 26

Circontrol Post eVolve Smart Series
152 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SERVICE MANUAL Post eVolve Smart
7 - CHARGE POINT SLAVE DEVICES
CIRCONTROL, S.A. Innovació, 3 08232 Viladecavalls (Barcelona)
Tel.: +34 937 362 940 Fax: +34 937 362 941 24
Web: www.circontrol.com E-mail: circontrol@circontrol.com
7.2.2.3 WIRING CONNECTION
Following image shows a detailed schematic of the connections in the CCL1-MINI PCB
and in each Plug. Please, refer to “7.2.1.4” section for more details.
7.2.2.4 CCL1-MINI WIRING CONNECTION
Following image shows a detailed schematic of the connections in the CCL1-MINI PCB.
Please, refer to TECHNICAL DATA” section for more details.
L3 L2
3 4
MCB
Q03.1
PLUG A
CEM-M-485
MCB
Q02.1
L1 N
-B
RS485B0-
+A
RS485A2+
3 4
PLUG B
CEM-M-485
L1 N
-B
RS485B2-
MCB
Q04.1
+A
RS485A0+
L1N
L3 L2 L1
CEM-C20
N
L3 L2 L1N
L3 L2 L1N
RS485-A+
RS485-B-
RS485-A2+
RS485-B2-

Table of Contents