SERVICE MANUAL Post eVolve Smart
7 - CHARGE POINT SLAVE DEVICES
CIRCONTROL, S.A. Innovació, 3 08232 Viladecavalls (Barcelona)
Tel.: +34 937 362 940 Fax: +34 937 362 941 23
Web: www.circontrol.com E-mail: circontrol@circontrol.com
11
Press and hold button from CEM-C20 for at least 2 seconds to “9600.
12
Press one time to arrive to “19200”.
13
Press two times to arrive to “DONE”, wait for “BAUD” to appear.
14
Press five times to arrive to “RETURN”.
15
Press and hold button from CEM-C20 for at least 2 seconds to
“SETUP”.
16
Press two times to arrive to “RETURN”.
17
Press and hold button from CEM-C20 for at least 2 seconds.
7.2.2.2 TECHNICAL CHARACTERISTICS
POWER SUPPLY
Voltage
230/127 VAC ±20%
Frequency
50…60Hz
Working temperature
-25…+70ºC
Relative humidity
5..95%
Maximum consumption
10 VA
SERIAL
Type
RS-485
Baud rate supported
9600, 19200, 38400
LOAD MEASUREMENT
Load Active energy measure accuracy
Class B (EN 50470)
Class 1 (IEC 62053-21)
Load reactive energy measure accuracy
Class 2.0 (IEC 62053-23)
Voltage
3 x 127/220...3 x 230/400 Vc.a.
Frequency
50…60Hz