SERVICE MANUAL Post eVolve Smart
9 - OPTIONAL DEVICES
CIRCONTROL, S.A. Innovació, 3 08232 Viladecavalls (Barcelona)
Tel.: +34 937 362 940 Fax: +34 937 362 941 55
Web: www.circontrol.com E-mail: circontrol@circontrol.com
EARTH LEAKAGE RELAY
Circuit
breaker
protection
Class
B
Sensibility
30 mA
Max current
Up to 125 A
Sensor
Built in earth leakage transformer 35 mm
Test and Reset
T & R buttons
Signalling LED
Power supply voltage
Leakage trip
Mechanical
Features
Operating temperature
-10...+50 ºC
Weight
380 g
Terminal dimensions
1-1.5 mm
2
Electrical
features
Operating voltage
230 Vac, 50/60 Hz
9.5.2.1 POWER SUPPLY WIRING CONNECTION
Following image shows a detailed schematic of the connections of the power supply to
the MCB and the Earth Leakage Relay. Please, refer to TECHNICAL DATAsection
for more details.
A1
A2
15
16
18
N
POWER SUPPLY
P1
P2
P3
Q04.1 (MCB OF PLUG A/B)
Earth leakage relay
MCB self-reclosing
Q03.1