2-528
Catalyst 2960 Switch Command Reference
OL-8604-03
Chapter 2 Catalyst 3750 Switch Cisco IOS Commands
show mls qos vlan
show mls qos vlan
Use the show mls qos vlan user EXEC command to display the policy maps attached to a switch virtual
interface (SVI).
show mls qos vlan vlan-id [ | {begin | exclude | include} expression]
Syntax Description
Command Modes User EXEC
Command History
Usage Guidelines The output from the show mls qos vlan command is meaningful only when VLAN-based quality of
service (QoS) is enabled and when policy maps are configured.
Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output
do not appear, but the lines that contain Output appear.
Examples This is an example of output from the show mls qos vlan command:
Switch> show mls qos vlan 10
Vlan10
Attached policy-map for Ingress:pm-test-pm-2
Related Commands
vlan-id Specify the VLAN ID of the SVI to display the policy maps. The range is 1 to
4094.
| begin (Optional) Display begins with the line that matches the expression.
| exclude (Optional) Display excludes lines that match the expression.
| include (Optional) Display includes lines that match the specified expression.
expression Expression in the output to use as a reference point.
Release Modification
12.2(25)FX This command was introduced.
Command Description
policy-map Creates or modifies a policy map that can be attached to
multiple ports and enters policy-map configuration mode.

Table of Contents

Other manuals for Cisco CATALYST 2960

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco CATALYST 2960 and is the answer not in the manual?

Cisco CATALYST 2960 Specifications

General IconGeneral
ManageableYes
StackingNo
ModelCatalyst 2960 Series Switches
Power over Ethernet (PoE)Available on some models (IEEE 802.3af)
VLANs255 active VLANs
FeaturesQoS
Operating Temperature32 to 113°F (0 to 45°C)
Relative Humidity10% to 85% non-condensing
Power ConsumptionVaries by model (30W to 400W)

Related product manuals