snmp-server enable traps
snmp-server enable traps
Use the snmp-server enable traps global configuration command to enable the switch to send Simple
Network Management Protocol (SNMP) notifications for various traps or inform requests to the network
management system (NMS). Use the no form of this command to return to the default setting.
snmp-server enable traps [bridge [newroot] [topologychange] | cluster | config | copy-config |
entity | envmon [fan | shutdown | status | supply | temperature] | errdisable
[notification-rate value] | flash | hsrp | ipmulticast | mac-notification | msdp | ospf
[cisco-specific | errors | lsa | rate-limit | retransmit | state-change] | pim
[invalid-pim-message | neighbor-change | rp-mapping-change] | port-security [trap-rate
value] | rtr | snmp [authentication | coldstart | linkdown | linkup | warmstart] |
storm-control trap-rate value | stpx [inconsistency] [root-inconsistency]
[loop-inconsistency] | syslog | tty | vlan-membership | vlancreate | vlandelete | vtp]
no snmp-server enable traps [bridge [newroot] [topologychange] | cluster | config | copy-config
| entity | envmon [fan | shutdown | status | supply | temperature] | errdisable
[notification-rate] | flash | hsrp | ipmulticast | mac-notification | msdp | ospf [cisco-specific
| errors |
lsa | rate-limit | retransmit | state-change] | pim [invalid-pim-message |
neighbor-change | rp-mapping-change] | port-security [trap-rate] | rtr | snmp
[authentication | coldstart | linkdown | linkup | warmstart] | storm-control trap-rate | stpx
[inconsistency] [root-inconsistency] [loop-inconsistency] | syslog | tty | vlan-membership |
vlancreate | vlandelete | vtp]
Syntax Description bridge [newroot]
[topologychange]
(Optional) Generate STP bridge MIB traps. The keywords have these
meanings:
newroot—(Optional) Enable SNMP STP Bridge MIB new root traps.
topologychange—(Optional) Enable SNMP STP Bridge MIB topology
change traps.
cluster (Optional) Enable cluster traps.
config (Optional) Enable SNMP configuration traps.
copy-config (Optional) Enable SNMP copy-configuration traps.
entity (Optional) Enable SNMP entity traps.
envmon [fan |
shutdown | status |
supply | temperature]
Optional) Enable SNMP environmental traps. The keywords have these
meanings:
fan—(Optional) Enable fan traps.
shutdown—(Optional) Enable environmental monitor shutdown traps.
status—(Optional) Enable SNMP environmental status-change traps.
supply—(Optional) Enable environmental monitor power-supply traps.
temperature—(Optional) Enable environmental monitor temperature
traps.
errdisable
[notification-rate
value]
(Optional) Enable errdisable traps. Use notification-rate keyword to set the
maximum value of errdisable traps sent per minute. The range is 0 to 10000;
the default is 0 (no limit imposed; a trap is sent at every occurrence).
flash (Optional) Enable SNMP FLASH notifications.
hsrp (Optional) Enable Hot Standby Router Protocol (HSRP) traps.

Table of Contents

Other manuals for Cisco CATALYST 2960

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco CATALYST 2960 and is the answer not in the manual?

Cisco CATALYST 2960 Specifications

General IconGeneral
ManageableYes
StackingNo
ModelCatalyst 2960 Series Switches
Power over Ethernet (PoE)Available on some models (IEEE 802.3af)
VLANs255 active VLANs
FeaturesQoS
Operating Temperature32 to 113°F (0 to 45°C)
Relative Humidity10% to 85% non-condensing
Power ConsumptionVaries by model (30W to 400W)