2-675
Catalyst 2960 Switch Command Reference
OL-8604-03
Chapter 2 Catalyst 3750 Switch Cisco IOS Commands
spanning-tree port-priority
spanning-tree port-priority
Use the spanning-tree port-priority interface configuration command to configure an interface
priority. If a loop occurs, spanning tree can find the interface to put in the forwarding state. Use the no
form of this command to return to the default setting.
spanning-tree [vlan vlan-id] port-priority priority
no spanning-tree [vlan vlan-id] port-priority
Syntax Description
Defaults The default is 128.
Command Modes Interface configuration
Command History
Usage Guidelines If the variable vlan-id is omitted, the command applies to the spanning-tree instance associated with
VLAN 1.
You can set the priority on a VLAN that has no interfaces assigned to it. The setting takes effect when
you assign the interface to the VLAN.
If you configure an interface with both the spanning-tree vlan vlan-id port-priority priority command
and the spanning-tree port-priority priority command, the spanning-tree vlan vlan-id port-priority
priority command takes effect.
vlan vlan-id (Optional) VLAN range associated with a spanning-tree instance. You can specify
a single VLAN identified by VLAN ID number, a range of VLANs separated by a
hyphen, or a series of VLANs separated by a comma. The range is 1 to 4094.
priority Number from 0 to 240, in increments of 16. Valid values are 0, 16, 32, 48, 64, 80,
96, 112, 128, 144, 160, 176, 192, 208, 224, and 240. All other values are rejected.
The lower the number, the higher the priority.
Release Modification
12.2(25)FX This command was introduced.

Table of Contents

Other manuals for Cisco CATALYST 2960

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco CATALYST 2960 and is the answer not in the manual?

Cisco CATALYST 2960 Specifications

General IconGeneral
ManageableYes
StackingNo
ModelCatalyst 2960 Series Switches
Power over Ethernet (PoE)Available on some models (IEEE 802.3af)
VLANs255 active VLANs
FeaturesQoS
Operating Temperature32 to 113°F (0 to 45°C)
Relative Humidity10% to 85% non-condensing
Power ConsumptionVaries by model (30W to 400W)