D15362.06 DX70 and DX80 Administrator Guide CE9.2, NOVEMBER 2017.   www.cisco.com — Copyright © 2017 Cisco Systems, Inc. All rights reserved. 
98
Cisco DX70 and DX80  Administrator Guide
Peripherals settings
Peripherals Profile ControlSystems
Define if a third-party control system, for example Crestron or AMX, is expected to be 
connected to the video system. This information is used by the video system's diagnostics 
service. If the number of connected control systems does not match this setting, the 
diagnostics service will report it as an inconsistency. Note that only one third-party control 
system is supported.
If set to 1, the control system must send heart beats to the video system using xCommand 
Peripherals Pair and HeartBeat commands. Failing to do so will cause the in-room control 
extensions to show a warning that the video system has lost connectivity to the control 
system.
Requires user role: ADMIN, INTEGRATOR
Default value: NotSet
Value space: 1/NotSet
1: One third-party control system should be connected to the video system. 
NotSet: No check for a third-party control system is performed.