set change-interval
To specify the number of hours over which a specified number of password changes can be made, use the set
change-interval command.
set change-interval num_hours
Syntax Description
The interval over which a users password changes are tallied to ensure they
do not exceed the maximum number specified with the set change-count
command; the number of hours can be 1 to 745.
num_hours
Command Modes
Password profile mode
Command History
ModificationRelease
Command added.1.1(1)
Usage Guidelines
The set change-during-interval option must be enabled before you can specify this interval.
Example
This example shows how to enter password profile mode, enable password-change restrictions, and
then specify that a user can change his or her password only twice in any 24-hour period:
FP9300-A # scope security
FP9300-A /security # scope password-profile
FP9300-A /security/password-profile # set change-during-interval enable
FP9300-A /security/password-profile* # set change-count 2
FP9300-A /security/password-profile* # set change-interval 24
FP9300-A /security/password-profile* # commit-buffer
FP9300-A /security/password-profile #
Related Commands
DescriptionCommand
Specifies the maximum number of times a locally authenticated user can change
his or her password.
set change-count
Enables or disables restrictions on the number of password changes a locally
authenticated user can make.
set change-during-interval
Cisco Firepower 4100/9300 FXOS Command Reference
173
S Commands
set change-interval

Table of Contents

Other manuals for Cisco Firepower 9300

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Firepower 9300 and is the answer not in the manual?

Cisco Firepower 9300 Specifications

General IconGeneral
ChassisModular
Security ModulesUp to 3
Firewall ThroughputUp to 1.2 Tbps
ManagementCisco Firepower Management Center
Form FactorRack-mountable
Number of Slots3
Encryption ThroughputUp to 100 Gbps
Operating Temperature32 to 104°F (0 to 40°C)
Humidity10% to 90% non-condensing
AltitudeUp to 10, 000 ft
Power SupplyDual, hot-swappable
Product TypeSecurity Appliance
Supported ModulesSecurity, network, and interface modules
RedundancyYes