Step 2 On the patch panel, locate the MPO cables and connectors.
Step 3 At the 40-WSS-C/40-WSS-CE card in the node, plug the MPO connector labeled 1 RX on an MPO cable
(Figure 4: MPO Cable, on page 36) into the top Add RX (30.3–35.8) port of the card.
Step 4 Plug the MPO connector labeled 2-RX into the Add RX (36.6–42.1) port on the card.
Step 5 Plug the MPO connector labeled 3-RX into the Add RX (42.9–48.5) port on the card.
Step 6 Plug the MPO connector labeled 4-RX into the Add RX (49.3–54.9) port on the card.
Step 7 Plug the MPO connector labeled 5-RX into the Add RX (55.7–61.4) port on the card.
When you close the patch panel tray, the cables must not be pinched, and the cable bend radius
must be equal to or greater than the minimum radius that is recommended in your site specifications.
As you route each cable through the patch panel tray, make sure that adequate cable slack remains.
The following figure shows the 40-channel patch panel ports and corresponding wavelengths.
Figure 12: 40-Channel (15454-PP-80) Patch Panel Port Wavelengths
Caution
Step 8 At the adjacent 40-DMX-C/40-DMX-CE card in the same side of the shelf, plug the MPO connector labeled
1 TX on the MPO cable into the top Drop TX (30.3–35.8) port of the card.
Step 9 Plug the MPO connector labeled 2-TX into the Drop TX (36.6–42.1) port on the card.
Step 10 Plug the MPO connector labeled 3-TX into the Drop TX (42.9–48.5) port on the card.
Step 11 Plug the MPO connector labeled 4-TX into the Drop TX (49.3–54.9) port on the card.
Step 12 Plug the MPO connector labeled 5-TX into the Drop TX (55.7–61.4) port on the card.
When you close the patch panel tray, the cables must not be pinched, and the cable bend radius
must be equal to or greater than the minimum radius that is recommended in your site specifications.
As you route each cable through the patch panel tray, make sure that adequate cable slack remains.
Caution
Step 13 Repeat Steps 2 through 12 to cable the other side of the shelf to the second patch panel.
Step 14 Return to your originating procedure (NTP).