5-6 Model D9858 Advanced Receiver Transcoder Installation and Operation Guide 4023074 Rev B
PE n: Loss of
Input
Set Loss of input
detected
Cause: Loss of input.
Remedy: Ensure
input has a valid
stream.
Loss of input. Minor
Clear Fault reset
Digital Program
Mapping
Set PID Collision Cause: Uplink
settings may have
changed since setting
up the unit. Please
check your DPM
settings.
Remedy: Correct
DPM settings. Check
the uplink to find
appropriate system
settings.
Two source
service PIDs are
being mapped to
the same output
PID. This will
cause data
corruption in the
stream.
Minor
Program Collision Two source
channel numbers
are being
mapped/passed
to the same
channel number
in the output.
Mode-i PMT out of
range
PMT PID to be
used for Mode-i
is outside of
valid MPEG PID
range.
Clear Digital Program
Mapping - OK
Shutdown Shutdown Event Major
SMI Setup Set Phase lock error on
SMI SDRAM
Cause: Hardware
Issue.
Remedy: Clear
alarms, reset unit,
and notify customer
service if problem
persists.
SDRAM on SMI
bus not working.
Major
SMI SDRAM exhaust
test failed
Clear SMI SDRAM setup
successful
SDRAM on SMI
Bus OK.
SMI SDRAM exhaust
test passed
Alarm Message
Type
Message Cause/Remedy Description Severity

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco PowerVu D9858 and is the answer not in the manual?

Cisco PowerVu D9858 Specifications

General IconGeneral
BrandCisco
ModelPowerVu D9858
CategoryTranscoder
LanguageEnglish