4023074 Rev B Model D9858 Advanced Receiver Transcoder Installation and Operation Guide 5-7
LMI setup Set LMI SDRAM exhaust
test failed
Cause: Hardware
issue.
Remedy: Clear
alarms, reset unit,
and notify customer
service if problem
persists.
DDR RAM on
LMI bus not
working.
Major
Clear LMI Video SDRAM
exhaust test passed
DDR RAM on
LMI bus OK.
PARAM
STORAGE
Set DB NVS flushing
ignored
Cause: Hardware
issue.
Remedy: Clear
alarms, reset unit,
and notify customer
service if problem
persists.
Non-volatile
storage system
failed to update
fully.
Major
RAM flush to NVS
failed
DB Factory Reset
failed
Non-volatile
storage system
failed during
factory reset.
Clear DB flushing
completed
Successful NVS
update.
DB Factory Reset
completed
Successful
action.
Flash STORAGE Set RECORD: init failed Cause: Hardware
issue.
Remedy: Clear
alarms, reset unit,
and notify customer
service if problem
persists.
Non-volatile
storage system
corrupted.
Possible loss of
configuration.
Major
RECORD
MANAGER: Record
contents check error,
erasing all
NVS Corruption,
and loss of
configuration
data
RECORD: sector
setup check error,
erasing sector
NVS Corruption,
and loss of sector
data
Clear RECORD: init done
LNB PS LNB PS Minor
Alarm Message
Type
Message Cause/Remedy Description Severity

Table of Contents