Page #149 background image
4023074 Rev B Model D9858 Advanced Receiver Transcoder Installation and Operation Guide 5-9
FPGA
Temperature
Alarm
Set Temperature over
Alarm threshold
Cause: Room
temperature too high,
or air flow is blocked.
Remedy: Check
openings on front
and rear panels for
blockage. Lower
room temperature or
improve air flow to
device.
FPGA
temperature is
above safe
operating range.
Major
Clear Clear Temperature
Alarm
Output Muted Set ASI Overflow.
Output Muted.
Reduce content.
Cause: Uplink
settings may have
changed since setting
up the unit. Variable
Bit Rate/Statmuxed
streams may be in
use.
Remedy: Increase
output rate, drop
unreferenced content
in DPM Options,
drop programs not
needed for
downstream devices.
Contact your service
provider (uplink) to
verify expected bit
rate settings.
Current
transport rate
exceeds
configured rate
for ASI output.
Output has been
muted to protect
downstream
devices.
Minor
MPEGoIP Overflow.
Output Muted.
Reduce content.
Current
transport rate
exceeds
configured rate
for MPEG over
IP output.
Output has been
muted to protect
downstream
devices.
Clear ASI Output Restored
MPEGoIP Output
Restored
ASI Out Status ASI Out Status Minor
MPoIP Status MPoIP Status Minor
Alarm Message
Type
Message Cause/Remedy Description Severity

Table of Contents