5-12 Model D9858 Advanced Receiver Transcoder Installation and Operation Guide 4023074 Rev B
Decoder
Processor Start
Set Secondary DB
Startup failed
Cause: Hardware
issue.
Remedy: Clear
alarms, reset unit,
and notify customer
service if problem
persists.
Transfer of
operational
parameters to
secondary
processor failed.
Major
Secondary App
Transfer Fail
Transfer of
Application SW
to second
processor was
not correctly
completed.
Secondary No
Response
Secondary
processor not
responding.
Secondary
Synchronization
Failure
Communication
with secondary
processor failing.
Clear Secondary Boot
passed
OK
Secondary Not
Booted (developer
override)
Specific message
used during
development. It
may indicate
that a front panel
key is stuck.
FPGA download Set FPGA Init failed to go
high
Cause: Hardware
issue
Remedy: Clear
alarms, reset unit,
and notify customer
service if problem
persists.
FPGA setup
failure
Major
FPGA Init and Done
failed to go low
FPGA Init went LOW
(CRC error)
FPGA Done failed to
go high
Invalid FPGA data
Invalid PCB version
Clear FPGA loaded
successfully
ASI/DHEI Out
Status
ASI/DHEI Out Status Minor
Alarm Message
Type
Message Cause/Remedy Description Severity