F180R MOTION Sensor User and Reference Guide
You can specify a duration (in seconds) that must elapse before the alarm will register a
change in state. This allows jitter in the alarm mechanism to be removed and report
significant events, rather than 'spike' events. For example, if this value was set to 2 then
if the alarm changed state, it would have to stay in the new state continuously for 2
seconds before it would be logged to the Alarm Log.
The Restore Defaults button resets to values to the default settings for an alarm
specification.
Figure 107: iHeave Status Bar
The Status Bar at the bottom of the iHeave display provides general information on the
availability of the iHeave output, the alarm status and the filter status.
5.6.6 iHeave Alarm Log
The Alarm Log area allows you to manage the status messages that the system reports.
Figure 108: Alarm Log
The functionality here includes :
Adding a user comment to the alarm status log
Saving the alarm status log to a text file
Clearing the alarm status log
Toggling the alarm log messages to repeat in the message log in the main MOTION
Control application