Software
Copyright © 2015 Coda Octopus Products Ltd
125
F180R MOTION Sensor User and Reference Guide
NOTE: The iHeave process runs automatically when MOTION Control is running. The
iHeave output will only be logged once you start logging data with MOTION Control. If
you close MOTION Control, you will also be shutting down the iHeave processing.
To replay and process any MCOM file the same procedure is applied.
Select the required MCOM file and start playing it back.
Start logging mode. The application will start recording a new _processed.mcom file and
a .csv file which can then be used for processing associated data sets requiring motion
data.
The processed MCOM data can also be re-transmitted via Ethernet to a network of your choice.
By selecting Home Tab -> Retransmit MCOM you can select a port number and Network IP
Address for the broadcast delivery of the iHeave processed MCOM data.
Figure 103: Retransmit MCOM
Normally you should not have to change this. However if you
have an application that is listening for the broadcast on a
particular port then you can change the port number
accordingly.
This is the network address that you want the broadcast
delivered on. If your host PC only has one network card then
you will only see one entry here. If the host PC is part of more
than one network then you should select the appropriate
network IP address.
5.6.3 iHeave Data Logging
With the F180R System fully configured and calibrated, you can start logging data from the
system. To log iHeave processed data, you must start data logging in MOTION Control. When
data logging is started the application will start writing the data files to the appropriate
storage directory.
To start logging data :
1. Select the Log Mode, Automatic or Manual in Logging Setup
2. Define a filename for manual logging or a destination directory for automatic logging -
see Logging Setup for moire information
3. Select the Start Logging button