F180R MOTION Sensor User and Reference Guide
Stop Logging
This menu will only be available after the logging was started.
Figure 69: Stop Logging Options
Stop Immediately - stops logging immediately.
NOTE: If the file is stopped immediately at the end of line, the iHeave filter will not
have enough collated data to compute processed heave to the end of the line.
Stop After iHeave Delay - stops logging automatically after the iHeave delay has expired. The
logged MCOM file will contain iHeave data up to the point that the button was clicked.
Stop After iHeave Delay and Start New File - stops logging after iHeave delay and starts a new
file.
NOTE: By using the any of the Stop after iHeave Delay options you can ensure that the
motion data acquired for your line will include enough data to allow computation of
processed iHeave throughout the full extent of the survey line length.
5.2.1.2 Data Source - Replay
As well as providing data outputs via serial strings and on the Ethernet network link, MOTION
Control also has the facility to log data to a file stored on the host PC. The data file, recorded in
MCOM format, captures all the information from the F180R System in real-time throughout
the survey. The resulting MCOM file can be played back and the recorded data can be viewed
in the application data displays.
NOTE: The played back MCOM does not generate the serial string outputs from the
serial ports.
In addition, the data can also be re-processed in playback using the iHeave functionality to
generate corrected heave output. The iHeave output is generated by default in real-time
mode however in playback mode you can alter the filter period characteristics and reprocess
the MCOM files.