F180R MOTION Sensor User and Reference Guide
Field
Description
Calibration Status
Unknown - The system is unable to determine the calibration
state. This is usually due to an invalid connection
Uncalibrated - A user-requested calibration is not in progress
and the F180R System has not reached a calibrated state.
In Progress - The system has been instructed to start a
calibration (via new settings uploaded from the MOTION
Settings Wizard) but has yet to reach the required
specification
Calibrated - The system has reached a calibrated state
Calibration Duration
The length of time the calibration process has been running
since first initialised
Heading Accuracy
Current heading accuracy value during calibration (See
Calibration Specification for further details)
Attitude Accuracy
Current attitude accuracy value during calibration (See
Calibration Specification for further details)
The bar across the Attitude Accuracy and Heading Accuracy graphs are Calibration Markers and
give an indication on how close your configuration is to the accuracy expected for calibration.
In addition to the calibration status summary, the Advanced State Variables show all of the
current calibration parameters. Select the Advanced button on the Calibration Status interface
to display them.
Save
Select Save to save the calibration settings to the F180R System when the calibration has
completed successfully. This commits the current calibration values to the system non-volatile
memory.
When the system reboots it will use the values last updated as its initial starting point for the
calibration.
The confirmation dialog will appear which you should confirm if want to proceed and commit
the settings to the F180R System.