2. Place the HPIA on the front of the reader.
3. Insert the lens cover mounting plate into the HPIA and secure them to the reader using the four M3 screws.
M3 x 16 mm screws
Note: Use a 3 mm hex wrench to torque the screws to 0.34 Nm (3 in-lb). Tighten in sequence.