EasyManua.ls Logo

Cognex DataMan 50 - Page 66

Cognex DataMan 50
173 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
M3 x 6.35 mm captive screws
Note: Use a 2 mm hex wrench to torque the captive screws to 0.34 Nm (3 in-lb). Tighten in sequence.
6. Attach the front cover.
M3 x 12mm captive screws
Note: Use a Phillips Screwdriver (PH0) to torque the captive screws to 0.31 Nm (2.75 in-lb). Tighten in
sequence.
Note: Remove the adhesive protective film from the front cover after attaching it.
Installing a C-Mount Lens
Note: The following steps describe service procedures for both the DataMan 370 and the 470 series readers, but
the images show only the DataMan 370.