EasyManua.ls Logo

Control Techniques COMMANDER SE

Control Techniques COMMANDER SE
195 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Commander SE Advanced User Guide 31
Issue Number: 4
There are eight deceleration rates programmable for normal operation, plus one for jogging. The ramp rates are expressed
as a time for a change of 100Hz on the ramp output, therefore, with a programmed ramp time of 10 seconds the ramp output
will decelerate from 50Hz to 0Hz in 5 seconds.
Although the deceleration rate can be set to 0.0, there is a minimum ramp time within the software of 0.1s/100Hz.
These bits are provided for control by logic input terminals for external ramp selection (see 2.10 & 2.20).
2.29 Jog deceleration rate
Ú
0.1 ~ 3200.0
Ö
0.2 s/100 Hz RW Uni
2.30 ~
2.31
Unused parameters
2.32 Acceleration select bit 0 (LSB)
2.33 Acceleration select bit 1
2.34 Acceleration select bit 2 (MSB)
2.35 Deceleration select bit 0 (LSB)
2.36 Deceleration select bit 1
2.37 Deceleration select bit 2 (MSB)
Ú
0 or 1
Ö
0 RO Bit
NOTE

Table of Contents

Other manuals for Control Techniques COMMANDER SE

Related product manuals