Commander SE Advanced User Guide 89
Issue Number: 4
3.12 Menu 12: Threshold detector
Parameter Range Type Default Setting Update Rate
12.01
Threshold detector output
indicator
0 or 1 RO Bit P L3
12.02 Not used
12.03 Threshold detector source
0.00 ~ 21.51
Menu.Parameter
RW Uni P 0.00 B
12.04 Threshold detector level 0.0 ~ 100.0% RW Uni 0.0 L3
12.05 Threshold detector hysteresis 0.0 ~ 25.0% RW Uni 0.0 L3
12.06 Threshold detector output invert 0 or 1 RW Bit 0 L3
12.07 Threshold detector destination
0.00 ~ 21.51
Menu.Parameter
RW Uni R P 0.00 I
12.08 Variable selector source 1
0.00 ~ 21.51
Menu.Parameter
RW Uni R P 0.00 I
12.09 Variable selector source 2
0.00 ~ 21.51
Menu.Parameter
RW Uni R P 0.00 I
12.10 Variable select bit 0 or 1 RW Bit 0 L3
12.11 Variable selector destination
0.00 ~ 21.51
Menu.Parameter
RW Uni R P 0.00 I