5-10
1010PVNFM-3A
Section 5
Notice: Controlotron holds US Patent Number 4,929,368 on the CC#122 Coupling Compound
and all compounds of this type. Its use is restricted to Controlotron products only, un-
LiquIdent S.G. Viscosity Visc. Slope Liquid Name K0 K1
1200 0.733 0.6 0.00001 LR (Leaded Regular) 192.4571 0.2438
1330 0.775 1.0 0.00001 KEROSENE 330.301 0.0
1350 0.818 1.16 0.00001 AVJET (AV Jet Fuel) 330.301 0.0
1380 0.819 1.95 0.00001 HSD (High Sulfur Diesel) 103.872 0.2701
1410 0.885 2.75 0.00001 LSD (Low Sulfur Diesel) 103.872 0.2701
1420 0.959 3.2 0.00001 GASSOIL (Sour Light Cycle Gas Oil) 103.872 0.2701
1490 0.9300 119.00 0.00001 FO (Fuel Oil) 103.872 0.2701
1579 0.9850 1049.00 0.00001 HFO (Heavy Fuel Oil) 103.872 0.2701
ITEM CC# USE CHARACTERISTICS
1 101 Temporary and portable use on Clamp-on Low in halogens and
flow transducers. Temp. range: -40°F to 100°F. sulfur content.
2 102 Temporary and portable use for all Clamp-on Low in halogens and sulfur
flow transducers. Well suited for survey use. content. Water soluble.
Temp. range: -30°F to 100°F.
3 109 Temporary and portable use for all Clamp-on Low viscosity Petroleum
flow transducers. Temp. range: -40°F to 300°F. product.
4 110 High temp. temporary couplant to be used Resists breakdown and
when setting up high temp. plastic flow trans- thinning out at high
ducers. Temp. range: 255°F to 450°F. temperatures.
5 111 Permanent high temp. couplant for plastic flow Room temperature vulcan-
transducers. Temp. range: 255°F to 450°F. izing silicone rubber.
6 112 Permanent ambient temperature couplant for Room temperature vulcan-
plastic flow transducers. Temp. range: -40°F izing silicone rubber.
to 250°F.
7 113 Protective spray for providing corrosion resis- Spray on liquid. Excellent
tance to exposed transducer and track parts. resistance to salt water
atmosphere.
8 114 Temporary and long term couplant for all flow Teflon filled grease.
transducer types. Temp. range: -40°F to 255°F. Water resistant.
9 117 Long term and permanent couplant for Silicone grease loaded with
Clamp-on transducers. Temp. range: -40°F to metal oxides. Resists Break-
450°F. down and thinning at high
temperatures.
10 120 Submersible couplant. To be used on all sub- Extremely water resistant.
merged transducer applications. Consult Controlotron
before using.
11 122 Long term and permanent couplant for Clamp- Long chain polymer
on transducers. Temp. range: -40°F to 450°F. grease. Resists breakdown
and thinning at high temp-
eratures.
12 124 Long term and permanent couplant for Clamp- Two part room temper-
on transducers. Temp. range: -40°F to 250°F. ature cure adhesive.
13 128 Temporary and long term couplant for all flow High viscosity silicone
transducer types. Temp. range: -40°F to 375°F. grease. Water resistant.
14 129 Adhesive backed Dry/Damping couplant for Viscoelastic polymer sheet.
129A all flow transducer types. Water resistant.
RECOMMENDED SONIC COUPLING COMPOUNDS