2.1.3 HOW TO CREATE/NAME A SITE SETUP
Use this command to create a new Site Setup. This is the first action required for an original
installation. Create/Name Site inserts system defaults in all the appropriate menu cells. You
can edit these defaults as necessary to suit your needs.
You do not have to provide a site name in order to create a new Site Setup. You can create a
site simply by pressing the <Right Arrow> to access the menu cell entry field and then press-
ing <ENT>. This creates a “nameless” Site Setup. However, if you intend to use the meter’s
multi-site storage facility, you must enter a unique site name for each site setup you want to
retain in site storage memory.
To Create and Name a new Site Setup:
To access the first character position press
To select a character press then to highlight to next character position.
To select the second character press
Repeat this process to select all the characters (8 max.) you want to use to identify the new
Site Setup.
To create the new Site Setup press
NOTE: If you decide to use numbers or a decimal point in the site name, you can type
these characters directly from the keypad.
2.1.4 HOW TO ENABLE/DISABLE SITE SECURITY
With Site Security enabled, the meter will require a password before it allows any activity
that could interrupt or affect system operation. You can still access the Installation Menu.
However, Site Security limits access to the viewing of parameters only. In other words, you
will still be able to review site data, but you will not be able to make any changes. The flowme-
ter will allow a <F4> Reset Sequence when Security is active, however, it also contains a
Menu Enable switch that allows you to inhibit this function (see drawing 1010N-7).
Activate Site Security with care. Once activated, the only way to deactivate it is via the Site
Security [Off] command. However, the cursor will not move to the Site Security option list
until you enter the correct password. Therefore,
it is essential that you never forget or mis-
place the password. The only way to deactivate Site Security without knowing the password
is to return the unit to Controlotron. However, the process the factory uses to remove Site
Security will eliminate any existing Site Data as well. Remember, your meter contains a menu
enable switch which also provides this function.
To activate Site Security:
To access the [Site Security] option list press
ENT
CAUTION: MAKE CERTAIN THAT YOU RETAIN A COPY OF THE PASSWORD
IN A SECURE LOCATION.