Preventative Maintenance 49
Cat. No. 01029401
Preventative Maintenance
Suggested Preventive Maintenance Inspection Schedule
The Culligan CTM commercial water softener has been designed to provide a good, consistent service life. Routinely
inspecting the system may help avoid potentially costly breakdowns related to circumstances outside of the control of the
dealer and/or user.
Table 9.
Component Suggested Inspection
Frequency
Reason for Maintenance
Entire System At Startup, after infrequent use
(idle for one week or more) or ev-
ery 3–6 months if on a private wa-
ter supply.
On private supplies, the appearance of off-tastes and
odors, particularly if musty or “rotten egg” (caused by harm-
less sulfate-reducing bacteria) may indicate a need for the
system to be sanitized. See “Sanitize the System” on page
48.
Drain Line Flow
Control
Every 12 months or every time ser-
vice is performed on the system.
Build up of sediment, iron and/or other foreign materials
(found in some water supplies but not necessarily all) could
negatively affect system performance.Monitor item for nor-
mal (or unexpected) wear.
Control Valve Every 6–12 months or every
time service is performed on the
system.
Build up of sediment, iron and/or other foreign materials
(found in some water supplies but not necessarily all) could
negatively affect system performance.Monitor item for nor-
mal (or unexpected) wear.
Softening Media Every 2–3 years Chlorinated water supplies can break-down/destroy resin
material. Resin material may also perform poorly if subject-
ed to other materials (sediment, iron, alum, etc) found in
some water supplies (but not necessarily all).
Pilot Strainer Every 6-12 months or every
time service is performed on the
system.
Build up of sediment, iron and/or other foreign materials
(found in some water supplies but not necessarily all) could
negatively affect system performance.Monitor item for nor-
mal (or unexpected) wear.
Softening Cartridge,
if equipped
Every 6-12 months or every
time service is performed on the
system.
Exhausted cartridge. Build up of sediment, iron and/or oth-
er foreign materials (found in some water supplies but not
necessarily all) could negatively affect system performance.
Monitor item for normal (or unexpected) wear.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Culligan CTM Series and is the answer not in the manual?

Culligan CTM Series Specifications

General IconGeneral
Power SourceElectric
Voltage120V
TypeCountertop
Dispensing OptionsCold
Filter Life6 months

Related product manuals