311
Figure 5-69
Step 2 Check the box to enable register function, set proxy server address, port, and
sub-device name at the device-end. Please enable the auto register function, the
device can auto register to the proxy server.
Parameter
Function
Server IP
address
The server IP address or server domain name you want to
register.
Port
The auto registration port value of the server.
Sub-device ID
The device ID allocated by the server.
Step 3 Click Save to complete the setup.
5.7.2.13 Alarm Centre
It is to set alarm center server. Once there is an alarm event, system can send out the
alarm to the alarm center. Please refer to chapter 4.14 Alarm events to set upload
function.
Step 1 From main window->Setup->Network->Alarm center.
Enter alarm center interface. See Figure 5-70.
Figure 5-70
Step 2 Refer to the following sheet for detailed information.
Parameter
Function
Enable
Check the box to enable alarm center function.
Server IP
The IP address and the communication port of the PC that has installed
the alarm client.
Port
Self-report time
Select alarm upload time from the dropdown list.
Step 3 Click Save to complete setup.