Web Operations 187
Ap Figure 5-72
Enter SSID information, select work band and verification type, and then enter the Step 3
connection password.
In the Work Band list, you can select 2.4G or 5G.
Select the Connection Password check box, the clear text password is displayed.
The default password is 12345678.
Click Save. Step 4
5.3.2.8 Configuring Auto Register Settings
After auto registration is succeeded, when the Device is connected into Internet, it will report
the current location to the specified server which acts as the transit to make it easier for the
Client software to access the Device.
Select SETUP > NETWORK > REGISTER. Step 1
The REGISTER interface is displayed. See Figure 5-73.
Register Figure 5-73
Select the Enable check box.(Selected by default) Step 2
Configure the parameters. For details, see Table 5-28. Step 3
Table 5-28 Register settings parameters description
In the Server IP box, enter the IP address or domain name of server to
register.
Enter the port of the server for register.
Unique ID for identifying Device. When different Devices register to the
same server, the IDs should be different.