Enter/Exit Programming Mode
Product Reference Guide
99
Character Conversion
Character conversion is an eight byte configuration item. The eight bytes
are 4 character pairs represented in hexadecimal ASCII values. The first
character in the pair is the character that will be converted. The second
character in the pair is the character to convert to. If the character to convert
in a pair is FF, then no conversion is done.
$CLFCH
Configure Character Conversion
DEFAULT
0xFFFFFFFFFFFFFFFF
(No character conversion)
If less than the expected string of 16 characters are selected, scan the
ENTER/EXIT bar code twice to accept the selections and exit Programming
Mode.