PDF417 Enter/Exit Programming Mode
Product Reference Guide  
                   231
PDF417 Set Length 1
Specifies one of the bar code lengths for PDF417 Length Control. Length 1 
is the minimum label length if in Variable Length Mode, or the first fixed 
length if in Fixed L
ength Mode. Length includes the bar code’s data charac-
ters only. Characters can be set from 00
01 to 2,710 characters (pad with 
zeroes) in increments of 01. Any value greater than 2,710 will be considered 
to be 2,710.
See page 283 for detailed instructions on setting this feature.
Select PDF417 Length 1 Setting
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar code 
at
 left followed by the digits from the Alphanumeric 
characters in
 Appendix D, Keypad 
representing 
your desired character(s). End by scanning the 
ENTE
R/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code t
o abort 
and not save the entry string. You can then start again 
at the beginning.
CANCEL
0001 = Length 1 is 1 Character