Enter/Exit Programming Mode
270
Gryphon™ I GD44XX/GBT4400/GM440X
Motion Sensitivity
Defines discrete set of levels for scanner motion sensitivity when in hand-
held use.
Motion Sensitivity = Low
Motion Sensitivity = Medium
Motion Sensitivity = High
Motionless Timeout
Specifies the waiting time in 100 millisecond ticks to assume that the reader
is in a motionless condition. The selectable range is 500 msec to 25.5 Sec-
onds. When no motion event is detected for a period of time longer than this
timeo
ut, the software assumes the reader is in a motionless condition. This
normally results in returning the scanner to Stand Mode. This option relates
to such features as Aimer On and Stand Mode Object Sense scanning with
respect to motion. See "Mo
tionless Timeout" on page 305 in References.
Select Motionless Timeout Setting
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar code
at le
ft followed by three digits from the Alphanumeric
characters in
Appendix D, Keypad
representing
your desired character(s). En
d by scanning the
ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL
bar code to abort
and not save the entry string. You can then start again
at the beginning.
CANCEL
020 = Motionless Timeout = 2 seconds