1D Code Selection Enter/Exit Programming Mode
Product Reference Guide
205
Code 93 Set Length 2
This feature specifies one of the bar code lengths for Code 93 Length Con-
trol. Length 2 is the maximum label length if in Variable Length Mode, or
the second fixed length if in Fixed Length Mode. Length includes the bar
code’s check, data, and full-ASCII shif
t characters. The length does not
include start/stop characters. The length can be set from 1 to 50 characters.
A setting of 0 specifies to ignore this length (only one fixed length).
Table 20 provides examples for setting Length 2. See page 283 for detailed
instructions on setting this feature.
Table 20. CODE 93 Length 2 Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting
00 (Ignore This
Length)
07 Characters 15 Characters 50 Characters
2 Scan ENTER/EXIT PROGRAMMING MODE
3 Scan SELECT CODE 93 LENGTH 2 SETTING
4
Scan Two Characters From
Appendix D, Keypad
‘0’ and ‘0’ ‘0’ and ‘7’ ‘1’ and ‘5’ ‘5’ AND ‘0’
5 Scan ENTER/EXIT PROGRAMMING MODE
$CC9L2
Select Code 93 Length 2 Setting
Make a mistake? Scan the CANCEL bar code to abort and not
save the entry string. You can then start again at the beginning.
~
CANCEL
DEFAULT
50 = Length 2 is 50 Characters

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Gryphon I GD44XX and is the answer not in the manual?

Datalogic Gryphon I GD44XX Specifications

General IconGeneral
BrandDatalogic
ModelGryphon I GD44XX
CategoryBarcode Reader
LanguageEnglish

Related product manuals