EasyManuals Logo

Datamax E-Class Mark II Programmer's Manual

Datamax E-Class Mark II
330 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #100 background imageLoading...
Page #100 background image
Extended System-Level Command Functions
88 Class Series 2 Programmer’s Manual
(PO) Paper Empty – This command sets the length of travel before an out of stock
condition is declared.
(PP) Parallel Direction – This command controls the parallel port communications
settings:
Value Parallel Direction Units / Interpretation
xz
x = Port ID: A or B
z = Direction: U (unidirectional – one-way communication); or,
B (bidirectional – IEEE 1284 back-channel operation).
Table 5-7: Parallel Communications Configuration Command
(PS) Present Sensor EquippedThis command allows the printer to sense the
present sensor option. A (or Y) - automatically senses device presence; if
undetected, no error will be generated. E - enables the device, where its presence
must be detected; otherwise, a fault is generated. N or D - disables device detection.
See <STX>V for command details. (Note that the value range for Non-Display models
is only Y, or N. Also see the <STX>KD command.)
(pS) Print Speed – See Label Formatting Command Function P for details.
(PT) Tear Position – This command sets the label stopping location at the tear
plate on the printer’s cover.
Not recommended for use with non-display models, instead see Stop Location (SL).

Table of Contents

Other manuals for Datamax E-Class Mark II

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datamax E-Class Mark II and is the answer not in the manual?

Datamax E-Class Mark II Specifications

General IconGeneral
Resolution203 dpi (8 dots/mm) or 300 dpi (12 dots/mm)
Operating Temperature40°F to 95°F (4°C to 35°C)
Storage Temperature-40°F to 140°F (-40°C to 60°C)
Print MethodDirect Thermal / Thermal Transfer
Max Print Speed6 inches per second (ips)
Memory8 MB DRAM
InterfaceSerial, Parallel, USB
Media TypeLabels, Tags, Receipts
Media Width0.75" (19 mm) to 4.65" (118 mm)
Media Thickness0.0025 to 0.008 inches (0.0635 to 0.2032 mm)
Power Requirements100-240 VAC, 50-60 Hz

Related product manuals