Extended System-Level Command Functions
Class Series 2 Programmer’s Manual 89
(PV) Paper Value – This command sets threshold value for the media sensor’s
“paper” parameter.
(PW) Password Set – This command modifies the numeric password required to
access the menu when security is enabled. If security is enabled, enter the new
password followed by the old password (with no spaces) in this form: XXXXXXXX
To be activated, the default password (0000) must be changed.
(QQ) Configuration Query – This command requires a parameter of either K or Q.
K causes the printer to respond with the Printer Key, used for generating Upgrade
Codes. A parameter value of Q causes the printer to respond with the current
configuration settings. The <STX>Kc response command stream format is sent to the
host computer via the same port as the query containing all parameters controlled
by the <STX>Kc command, and may be used for restoring the printer’s configuration
or for configuring other printers.
(RA) Row Adjust This command shifts the vertical start of print position (in
dots). Note that the EX2 accepts this command for backward compatibility only,
limited in range (28-228). <STX>KcQQQ response shows the Row Adjust Fine Tune
(RF) equivalent value.
(RE) Ribbon Saver Equipped This command allows the printer to sense the
ribbon saver option. A (or Y) - automatically senses device presence; if undetected,
no error is generated. E - enables the device, where its presence must be detected;
otherwise, a fault is generated. N or D - disables device detection. See <STX>R for
command details.
(RF) Row Adjust Fine Tune – This command shifts the vertical start of print
position in dots (see Appendix K) upward or downward.

Table of Contents

Other manuals for Datamax E-Class Mark II

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datamax E-Class Mark II and is the answer not in the manual?

Datamax E-Class Mark II Specifications

General IconGeneral
Resolution203 dpi (8 dots/mm) or 300 dpi (12 dots/mm)
Operating Temperature40°F to 95°F (4°C to 35°C)
Storage Temperature-40°F to 140°F (-40°C to 60°C)
Print MethodDirect Thermal / Thermal Transfer
Max Print Speed6 inches per second (ips)
Memory8 MB DRAM
InterfaceSerial, Parallel, USB
Media TypeLabels, Tags, Receipts
Media Width0.75" (19 mm) to 4.65" (118 mm)
Media Thickness0.0025 to 0.008 inches (0.0635 to 0.2032 mm)
Power Requirements100-240 VAC, 50-60 Hz