Appendix J – General Purpose Input Output Port Applications
Class Series 2 Programmer’s Manual 263
Failure to properly configure the GPIO Port can result in damage to the printer and / or connected devices.
Applicator Interface Card (Type 2) GPI/O Port B Overview
Pin Number
Signal Name /
Direction
[1]
Jumper Position Function / Description
Installed
Printer +5VDC is used (.5 amp maximum).
Drawing more than .5 amps can cause unreliable printer operation.
1 +5 VDC JMP 11
Removed +5VDC must be supplied.
2 Input 6 N/A N/A Programmed input function.
3 Input 3 N/A N/A Programmed input function.
Installed: Pins 1 – 2 Programmed output function pulled-up to +5VDC.
Installed: Pins 2 – 3 Programmed output function pulled-up to +24VDC.
4 Output 6 JMP 7
Removed An external voltage via external pull-ups determine this level, not exceed +30VDC.
Installed: Pins 1 – 2 Programmed output function pulled-up to +5VDC.
Installed: Pins 2 – 3 Programmed output function pulled-up to +24VDC.
5 Output 3 JMP 4
Removed An external voltage via external pull-ups determine this level, not exceed +30VDC.
Installed Printer chassis is used.
6 Ground JMP 10
Removed Ground must be supplied.
7 Input 5 N/A N/A Programmed input function.
8 Input 2 N/A N/A Programmed input function.
Installed: Pins 1 – 2 Programmed output function pulled-up to +5VDC.
Installed: Pins 2 – 3 Programmed output function pulled-up to +24VDC. 9 Output 5 JMP 6
Removed An external voltage via external pull-ups determine this level, not exceed +30VDC.
Installed: Pins 1 – 2 Programmed output function pulled-up to +5VDC.
Installed: Pins 2 – 3 Programmed output function pulled-up to +24VDC.
10 Output 2 JMP 3
Removed An external voltage via external pull-ups determine this level, not exceed +30VDC.
11 +24 VDC N/A N/A Printer +24 VDC (1.5 amp maximum).
12 Input 4 N/A N/A Programmed input function.
13 Input 1 N/A N/A Programmed input function.
Installed: Pins 1 – 2 Programmed output function pulled-up to +5VDC.
Installed: Pins 2 – 3 Programmed output function pulled-up to +24VDC.
14 Output 4 JMP 5
Removed An external voltage via external pull-ups determine this level, not exceed +30VDC.
Installed: Pins 1 – 2 Programmed output function pulled-up to +5VDC.
Installed: Pins 2 – 3 Programmed output function pulled-up to +24VDC.
15 Output 1 JMP 2
Removed An external voltage via external pull-ups determine this level, not exceed +30VDC.
[1]
Signal directions are given relative to the printer.

Table of Contents

Other manuals for Datamax E-Class Mark II

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datamax E-Class Mark II and is the answer not in the manual?

Datamax E-Class Mark II Specifications

General IconGeneral
Resolution203 dpi (8 dots/mm) or 300 dpi (12 dots/mm)
Operating Temperature40°F to 95°F (4°C to 35°C)
Storage Temperature-40°F to 140°F (-40°C to 60°C)
Print MethodDirect Thermal / Thermal Transfer
Max Print Speed6 inches per second (ips)
Memory8 MB DRAM
InterfaceSerial, Parallel, USB
Media TypeLabels, Tags, Receipts
Media Width0.75" (19 mm) to 4.65" (118 mm)
Media Thickness0.0025 to 0.008 inches (0.0635 to 0.2032 mm)
Power Requirements100-240 VAC, 50-60 Hz