Figure 43. Installing the thermal sensor board
Next steps
1. Install the diskless 80 mm fan cage.
2. Install all the 80 mm fans.
3. Install the mid top cover.
4. Install the system cover.
5. Follow the procedure listed in After working inside your system.
Midplane
This is a service technician replaceable part only.
Removing the right midplane
Prerequisites
NOTE:
Observe the routing of the cables on the chassis as you remove them from the system. Route these cables properly
when you replace them to prevent the cables from being pinched or crimped.
1. Follow the safety guidelines listed in Safety instructions.
2. Follow the procedure listed in Before working inside your system.
3. Remove all the sleds from the enclosure.
4. Disconnect all the cables, except the power cables.
Steps
1. Using the Phillips 1 screwdriver, remove the screws securing the midplane to the chassis.
2. Using the Phillips 2 screwdriver, remove the screws securing the right power cables to the chassis management board.
3. Pull the midplane to the front of the enclosure and lift the midplane out of the chassis.