EasyManua.ls Logo

Dell PowerEdge C6600 - Control Panel; Removing the Left Control Panel

Dell PowerEdge C6600
103 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2. Install the power interposer board.
3. Install the power supply units.
4. Follow the procedure listed in After working inside your system.
Control panel
This is a service technician replaceable part only.
Removing the left control panel
Prerequisites
NOTE: Observe the routing of the cables on the system as you remove them. You must route these cables properly when
you replace them to prevent the cables from being pinched or crimped.
1. Follow the safety guidelines listed in Safety instructions.
2. Follow the procedure listed in Before working inside your system.
3. Remove the mid top cover.
4. Remove the 80 mm fans.
5. Remove the diskless 80 mm fan cage.
6. Disconnect control panel cables from the midplane.
Steps
1. Using the Phillips 1 screwdriver, remove the screws securing the left control panel assembly to the chassis.
2. Remove the cable from the cable retention clips.
3. Lift the left control panel assembly from the system.
Figure 62. Removing the left control panel assembly
62
Installing and removing system components

Table of Contents

Related product manuals