User Manual DEV 1951
108 Copyright DEV Systemtechnik GmbH 2004-2017
5.9.4.3 .application
5.9.4.3.1 .application.controlMode
OID: .1.3.6.1.4.1.21035.41.2.1.0
Syntax: INTEGER {local (1), remote (2), auto (3)}
Access: read-write OR read-only
Description: The device operation mode (chapter 5.1), possible values:
"1" Local Mode: local operation at the device or
via Web Interface
"2" Remote Mode: remote operation e.g. via SNMP
"3" Auto Mode: the usage of the device is defined by the
Auto Mode Assignment of the Web Interface
(please refer to chapter 5.5.7.3.2)
Note:
Via the SNMP setup of the Web Interface (chapter 5.5.7.2.2), .controlMode can
be set to read-write (default) or to read-only.
The factory setting is "2" (Remote Mode).
5.9.4.3.2 .application.switchingControl
OID: .1.3.6.1.4.1.21035.41.2.2.0
Syntax: INTEGER32
Access: read-write
Description: .switchingControl is still present due to backward compatibility
reasons; i.e. it has no effect on the functionality of the device.