User Manual DEV 1951
Copyright DEV Systemtechnik GmbH 2004-2017 115
5.9.4.3.9.2 .application.portTable.portEntry.poEnable
OID: .1.3.6.1.4.1.21035.41.2.9.1.2.x
Syntax: INTEGER {disabled (1), enabled (2)}
Access: read-write
Description: Events possibly caused by the port are (or can be) enabled or
disabled. Additionally this setting influences the switching behavior
of a device with applied sensing switch modules or digital signal
switch modules in Auto Mode with activated autonomous
switching functionality; please refer to chapter 5.1.3.1.
Note:
It is possible to enable or to disable any of the ports in the .portTable but this
makes sense only for ports that are capable of generating port specific events.
The factory setting is "2" (enabled) for all ports.
5.9.4.3.9.3 .application.portTable.portEntry.poType
OID: .1.3.6.1.4.1.21035.41.2.9.1.3.x
Syntax: INTEGER32 (0..255)
Access: read-only
Description: The functionality of the port, possible values:
"0" common output port of a switch module
"1" primary input port of a module
(switch module or distribution amplifier module)
"2" secondary input port of a switch module
5.9.4.3.9.4 .application.portTable.portEntry.poHasRfSense
OID: .1.3.6.1.4.1.21035.41.2.9.1.4.x
Syntax: INTEGER {yes (1), no (2)}
Access: read-only
Description: The indication whether RF level information is provided or not.
Note:
"1" (yes) is returned for the input ports of sensing switch modules (or of digital
signal switch modules) and for the input port of distribution amplifier modules,
otherwise "2" (no).
5.9.4.3.9.5 .application.portTable.portEntry.poRfSense
OID: .1.3.6.1.4.1.21035.41.2.9.1.5.x
Syntax: INTEGER32
Access: read-only
Description: The measured RF level in [dBm/10].
"9999" means not available or not present.
Example: "-129" ≡ -12.9 dBm (only for input ports of sensing switch modules)