User Manual DEV 1951
116 Copyright DEV Systemtechnik GmbH 2004-2017
5.9.4.3.9.6 .application.portTable.portEntry.poRfLimit
OID: .1.3.6.1.4.1.21035.41.2.9.1.6.x
Syntax: INTEGER32
Access: read-write
Description: The RF threshold level in [dBm/10].
"9999" means not available or not present.
Example: "-300" ≡ -30.0 dBm (only for input ports of sensing switch modules)
Note:
For older sensing switch modules (with potentiometers to adjust the threshold
level) which are not capable to be adjusted via software, "-300" is returned.
A set command is accepted, but the value is not stored.
The factory setting is stated in chapter 4.3.1.
5.9.4.3.9.7 .application.portTable.portEntry.poHasBias
OID: .1.3.6.1.4.1.21035.41.2.9.1.7.x
Syntax: INTEGER {yes (1), no (2)}
Access: read-only
Description: The indication whether bias (i.e. LNB power) is provided or not.
For this type of device, "2" (no) is returned for all ports.
5.9.4.3.9.8 .application.portTable.portEntry.poBiasOnOff
OID: .1.3.6.1.4.1.21035.41.2.9.1.8.x
Syntax: INTEGER {on (1), off (2)}
Access: read-write
Description: The LNB power (or bias) supply state can be read or set.
For this type of device, "0" is returned for all ports.
5.9.4.3.9.9 .application.portTable.portEntry.poBiasCurrent
OID: .1.3.6.1.4.1.21035.41.2.9.1.9.x
Syntax: INTEGER32
Access: read-only
Description: The measured current in [mA/10].
For this type of device, "9999" is returned for all ports.
5.9.4.3.9.10 .application.portTable.portEntry.poBiasLimitLo
OID: .1.3.6.1.4.1.21035.41.2.9.1.10.x
Syntax: INTEGER32 (0..3000)
Access: read-write
Description: The lower limit of the current monitoring interval in [mA/10].
For this type of device, "9999" is returned for all ports.
5.9.4.3.9.11 .application.portTable.portEntry.poBiasLimitHi
OID: .1.3.6.1.4.1.21035.41.2.9.1.11.x
Syntax: INTEGER32 (3000..6000)
Access: read-write
Description: The upper limit of the current monitoring interval in [mA/10].
For this type of device, "9999" is returned for all ports.