5.9.4.3.3 .application.simultaneousMode
OID: .1.3.6.1.4.1.21035.41.2.3.0
Syntax: INTEGER {simultaneous (1), individual (2)}
Access: read-write
Description: The switching mode (please refer to chapter 5.1.4), possible values:
"1" in Simultaneous switching mode
both switch modules are switched synchronously
"2" in Individual switching mode
(both) switch modules can be switched independently
Note:
.simultaneousMode cannot be set to "1" if
if the device is equipped with one switch module only, or
if the device is equipped with one or two distribution amplifier modules, or
with two switch modules installed being not in the same switch position.
5.9.4.3.4 .application.numberOfSwitchGroups
OID: .1.3.6.1.4.1.21035.41.2.4.0
Syntax: INTEGER32
Access: read-only
Description: The number of switch groups.
Note:
For .numberOfSwitchGroups "1" is returned independently whether the device
is equipped with one or two switch modules.
This value is used to determine the maximum index of the following table:
5.9.4.3.5 .application.switchGroupTable
"1" is returned for .numberOfSwitchGroups (please refer to chapter 5.9.4.3.4), thus
a single entry per .switchGroupTable OID. The table is used for the assignment of
switch units (here: switch modules) to groups which is required for simultaneous
switching applications.
5.9.4.3.5.1 .application.switchGroupTable.switchGroupEntry.swGroupIndex
OID: .1.3.6.1.4.1.21035.41.2.5.1.1.x
Syntax: INTEGER32 (1..32)
Access: not-accessible
Description: A unique value for each table entry ranging between "1" and the
number of entries (defined by .numberOfSwitchGroups, please
refer to chapter 5.9.4.3.4).
5.9.4.3.5.2 .application.switchGroupTable.switchGroupEntry.swGroupMembers
OID: .1.3.6.1.4.1.21035.41.2.5.1.2.x
Syntax: OCTET STRING
Access: read-write
Description: A comma separated string that is interpreted as integers containing
the indices of the switch units being member of the switch group.
Here, for the single existing switch group "1,2" is returned.