User Manual DEV 1951
110 Copyright DEV Systemtechnik GmbH 2004-2017
5.9.4.3.5.3 .application.switchGroupTable.switchGroupEntry.swGroupMainRfStatus
OID: .1.3.6.1.4.1.21035.41.2.5.1.3.x
Syntax: INTEGER {ok (1), notok (2), notapplicable (3)}
Access: read-only
Description: The (RF or digital) signal status for the main ports (here: the
primary input ports) of the switch units being member of the single
existing switch group, possible values:
"1" ok: the signal status of all primary input ports is above the
defined RF threshold level or "OK"
"2" not ok: the signal status of at least one primary input port
is below the defined RF threshold level or "Fail"
"3" not applicable: is returned if the signal status cannot be
assessed
Note:
Only if the DEV 1951 is equipped with two sensing switch modules or digital
signal switch modules (or with a mix of both types) it is possible to judge the
signal quality. In all other cases, this is not possible and thus "3" is returned.
The digital signal switch modules are capable to make an assessment regarding
the digital signal quality, thus the name .swGroupMainRfStatus is not quite
appropriate.
5.9.4.3.5.4 .application.switchGroupTable.switchGroupEntry.swGroupRedundancyRfStatus
OID: .1.3.6.1.4.1.21035.41.2.5.1.4.x
Syntax: INTEGER {ok (1), notok (2), notapplicable (3)}
Access: read-only
Description: The (RF or digital) signal status for the redundancy ports (here: the
secondary input ports) of the switch units being member of the
single existing switch group, possible values:
"1" ok: the signal status of all secondary input ports is above the
defined RF threshold level or "OK"
"2" not ok: the signal status of at least one secondary input port
is below the defined RF threshold level or "Fail"
"3" not applicable: is returned if the signal status cannot be
assessed
Note:
Only if the DEV 1951 is equipped with two sensing switch modules or digital
signal switch modules (or with a mix of both types) it is possible to judge the
signal quality. In all other cases, this is not possible and thus "3" is returned.
The digital signal switch modules are capable to make an assessment regarding
the digital signal quality, thus the name .swGroupRedundancyRfStatus is not
quite appropriate.