EasyManua.ls Logo

DEV 1951 - Application.switchunittable.switchunitentry.swmembers

DEV 1951
135 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
User Manual DEV 1951
112 Copyright DEV Systemtechnik GmbH 2004-2017
5.9.4.3.7.3 .application.switchUnitTable.switchUnitEntry.swMembers
OID: .1.3.6.1.4.1.21035.41.2.7.1.3.x
Syntax: OCTET STRING
Access: read-only
Description: A comma separated string that is interpreted as integers, con-
taining the indices of the ports in the .portTable (please refer to
chapter 5.9.4.3.9) being member of the switch unit (here: switch
module).
Note:
If only a single switch module, or if one switch module and one distribution
amplifier module, or if two distribution amplifier modules are installed, one or
two logical switch modules are added by the firmware (chapter 5.9.4.3.9).
Thus, the port assignment is static and the response of .swMembers is always
as if two real switch modules were installed. For instance, "1,2,5," is returned
for .swMembers.1 (for the switch module in slot 1 with: "1" = primary input
port, "2" = secondary input port, & "5" = output port), i.e.:
.swMembers
.i
Primary Input
Port
Secondary Input
Port
Output
Port
1
1
2
5
2
3
4
6
5.9.4.3.7.4 .application.switchUnitTable.switchUnitEntry.swPosition
OID: .1.3.6.1.4.1.21035.41.2.7.1.4.x
Syntax: INTEGER32
Access: read-write
Description: The switching status of the corresponding switch unit (here: switch
module). By writing to .swPosition the switching state can be
altered, possible values:
"1" the unit is (to be) switched to the primary input port
"2" the unit is (to be) switched to the secondary input port
Note:
.swPosition is used to perform the switching via SNMP in Remote Mode.
If a switch unit representing a logical switch module (please refer to chapter
5.9.4.3.9) is commanded to switch via a "Set" command issued to .swPosition,
this command is accepted, but the value remains "1".
If .simultaneousMode (chapter 5.9.4.3.3) is set to "1" (i.e. Simultaneous
switching mode), a "Set" command issued to .swPosition of a switch unit will
cause all members of the group (to which the switch unit belongs to) to switch.

Table of Contents