5.9.4.3.9.12 .application.portTable.portEntry.poHasGain
OID: .1.3.6.1.4.1.21035.41.2.9.1.12.x
Syntax: INTEGER {yes (1), no (2)}
Access: read-only
Description: The indication whether gain control is provided or not.
For this type of device, "2" (no) is returned for all ports.
5.9.4.3.9.13 .application.portTable.portEntry.poGain
OID: .1.3.6.1.4.1.21035.41.2.9.1.13.x
Syntax: INTEGER32
Access: read-write
Description: The gain control value in [dB/10].
For this type of device, "9999" is returned for all ports.
5.9.4.3.9.14 .application.portTable.portEntry.poHasTilt
OID: .1.3.6.1.4.1.21035.41.2.9.1.14.x
Syntax: INTEGER {yes (1), no (2)}
Access: read-only
Description: The indication whether slope (or tilt) control is provided or not.
For this type of device, "2" (no) is returned for all ports.
5.9.4.3.9.15 .application.portTable.portEntry.poTilt
OID: .1.3.6.1.4.1.21035.41.2.9.1.15.x
Syntax: INTEGER32
Access: read-write
Description: The slope (or tilt) setting in [dB/10].
For this type of device, "0" is returned for all ports.
5.9.4.3.9.16 .application.portTable.portEntry.poCardType
OID: .1.3.6.1.4.1.21035.41.2.9.1.16.x
Syntax: OCTET STRING (SIZE(32))
Access: read-only
Description: The DEV name for the module to which the port belongs.
Examples: "11-0010" for a DEV 11-0010 sensing switch module
"PCF_ABSwitch" for a DEV 11-0005 switch module or
for "logical" switch modules (chapter 5.9.4.3.9))